 Oven Controlled Crystal Oscillator
OX-501
Preliminary
Features 6-Pin SMD package Fast Warm-up TCXO Replacement for better short term stability Typical Applications Base Stations Test Equipment Femto Basestation Military Communication Equipment
Frequency Range Standard Frequencies
10 MHz - 100 MHz 10; 12.8; 16.384; 19.44; 20.00; 30.72; 38.88; 51.84 MHz
Frequency stabilities1 [AT Cut Crystal-Standard-10 to 100 MHz]
Parameter
vs. operating temperature range (Referenced to +25C)
Min
-100 -250 -250
Typ
Max
+100 +250 +250
Units
ppb ppb ppb Units ppm ppb ppb ppb ppb ppb minutes
Operating temperature range
-20 ... +70C -20 ... +70C -40... +85C Condition at time of shipment, nominal EFC VS 5% static Load 5% static after 30 days of operation 60MHz; >60MHz; after 30 days of operation after 30 days of operation
Parameter
Initial tolerance vs. supply voltage change vs. load change vs. aging vs aging vs. aging / day / year / year
Min -0.5 -20 -20 -10 -300 -500
Typ
Max +0.5 +20 +20 +10 +300 +500 2
Warm-up Time
to 200ppb of final frequency (1 hour reading) @ +25C
htttp://www.vectron.com Vectron International*267 LowellRoad, Hudson, New Hampshire 03051*Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG * Landstrae, 74924 Neckarbischofsheim, Germany * Tel: +49 7268 801 100 OX-501 page: 1/5
Options5
Frequency stabilities1 [SC Cut Crystal-Option-10 to 52 MHz]
Parameter
vs. operating temperature range (Referenced to +25C)
Min
-30 -50
Typ
Max
+30 +50
Units
ppb ppb
Operating temperature range
-20 ... +70C -40... +85C Options5
Parameter
Initial tolerance vs. supply voltage change vs. load change vs. aging vs aging vs. aging / day / year / year
Min
-0.2 -10 -10 -5.0 -100 -500
Typ
Max
+0.2 +10 +10 +5.0 +100 +500 2
Units
ppm ppb ppb ppb ppb ppb minutes
Condition
at time of shipment, nominal EFC VS 5% static Load 5% static after 30 days of operation 60MHz; >60MHz; after 30 days of operation after 30 days of operation
Warm-up Time
to 100ppb of final frequency (1 hour reading) @ +25C
Supply Voltage (Vs)
Parameter
Supply voltage [Standard] Power consumption
Min
3.135
Typ
3.3
Max
3.465 2.2 0.7
Units
VDC Watts Watts
Condition
during warm-up steady state @ +25C
RF Output
Parameter
Signal [Standard] Load Signal Level (Vol) Signal Level (Voh) Duty cycle
Min
Typ
HCMOS 15
Max
Units
pF
Condition
0.4 2.4 45 55
VDC VDC %
with Vs=3.3V and 15pF load with Vs=3.3V and 15pF load @ (Voh-Vol)/2
htttp://www.vectron.com Vectron International*267 LowellRoad, Hudson, New Hampshire 03051*Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG * Landstrae, 74924 Neckarbischofsheim, Germany * Tel: +49 7268 801 100 OX-501 page: 2/5
Frequency Tuning (EFC)
Parameter
Tuning Range Tuning Range 5.0 1.0 Linearity Tuning Slope Control Voltage Range 0.0 1.4 10% Positive 2.8 VDC with Vs=3.3V
Min
Typ
Max
12 3
Units
ppm ppm
Condition
with AT cut Crystal with SC cut Crystal
Fixed OCXO; No adjust
Additional Parameters
Parameter
Phase Noise3
Min
Typ
Max
-65 -95 -120 -140 -145
Units
dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz g 1 10 100 1 10 Hz Hz Hz kHz kHz
Condition
@ 10 MHz
Weight Processing & Packing
8.0 Handling & Processing Note
Absolute Maximum Ratings
Parameter
Supply voltage (Vs) Output Load Operable temperature range Storage temperature range -55 -55
Min
Typ
Max
5.5 50 +85 +125
Units
V pF C C
Condition
with Vs=5.0VDC
Notes:
1 Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies. 2 Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25C) 3 Phase noise degrades with increasing output frequency. 4 Subject to technical modification. 5 Contact factory for availability.
htttp://www.vectron.com Vectron International*267 LowellRoad, Hudson, New Hampshire 03051*Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG * Landstrae, 74924 Neckarbischofsheim, Germany * Tel: +49 7268 801 100 OX-501 page: 3/5
Options5
Enclosure
OX-501
Height "H" 9,9 Pin Length "L" N.A
Pin Connections
1 Electronic Frequency Control Input (EFC) 2 Enable 3 Ground (Case) 4 RF Output 5 Uref 6 Supply Voltage Input
Standard Shipping Methode (For OX-501 Type)
A X B P
*bei W 24 mm nur untere Lochreihe by W 24 mm only lower hole line
Lage im Gurt Position in tape Pin 1
Abwickelrichtung Unwinding direction
K
Gurtunterseite Tape buttom side Gurtoberseite Tape upper side
Production tolerance complying DIN IEC 286-3
Enclosure Type
Typ OX-501
Tape width W [mm]
N.A
Quantity per meter
N.A
Quantity per reel
N.A
Dimension P
N.A
htttp://www.vectron.com Vectron International*267 LowellRoad, Hudson, New Hampshire 03051*Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG * Landstrae, 74924 Neckarbischofsheim, Germany * Tel: +49 7268 801 100 OX-501 page: 4/5
Recommanded Reflow Profile
Profile Feature
Average ramp-up rate (TL to Tp) Preheat -Temperature Min TSmin -Temperature Min Tsmax -Time (min to max) tS
Pb-Free Assembly/ Sn-Pb Assembly
3C/second max. 150C 200C 60-180 seconds 3C/second max 217C 60-150 seconds max 260C
Profile Feature
Time 25C to Peak Temperature Time maintainted above -Temperature (TL) -Time (tL)
Pb-Free Assembly/ Sn-Pb Assembly
8 minutes max. 217C 60-150 seconds
TSmax to TL-Ramp-up Rate Time maintainted above -Temperature (TL) -Time (tL) Peak Temperature (TP)
Time within 5C of actual Peak Temperature (tP) Ramp-down Rate
20-40 seconds 6C/ second max
Note: All temperatures refer to topside of the package, measured on the package body surface.
How to order this product:
Use this worksheet to forward the following information to your factory representative : Model
OX-501
Height
0
-
Supply Voltage Code
B
RF Output Code
A
Temperatur Range
E
-
Stability
108
Frequency Control
0
-
Frequency
10MHz
Model Code: 501: SMD Version Height: 0: 9,9 mm Supply Voltage Code: E: 3,3 V RF Output Code: A: HCMOS
Frequency Control: 0: No Tuning 1: 5.0...12 ppm 2: 1.0...3.0 ppm Temperature Range: E: -40...+85C J: -20...+70C P: 0...+50C Stability Code: 258: 508: 107: 257: 25ppb 50ppb 100ppb 250ppb
htttp://www.vectron.com Vectron International*267 LowellRoad, Hudson, New Hampshire 03051*Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG * Landstrae, 74924 Neckarbischofsheim, Germany * Tel: +49 7268 801 100 OX-501 page: 5/5


▲Up To Search▲   

 
Price & Availability of OX-501

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X